VSP ™ (Voltage Sag Protector) Instantaneous low protection, instant low countermeasure, instant low compensation
Please feel free to contact us if you have any problems with your existing UPS or other protection products.
Cause of instantaneous voltage drop (instantaneous voltage drop / instantaneous power failure)
Power outages at Japanese electric power companies are considerably less than in other countries, and although there are regional differences, instantaneous voltage drops (instantaneous voltage drop or instantaneous power failure) of about 0.06 to 2 seconds occur several to several tens of times a year. It is occurring. Mostly due to lightning strikes on the transmission lines, the duration is the time it takes to disconnect the transmission line whose voltage has dropped due to the lightning strike. According to statistics, a five-year survey of power supply problems at a facility shows that the voltage drops. The results show that 8% of the cases are "instantaneous low within 0.2 seconds" and "instantaneous voltage drop rate of 20% or more" occurs about 5 times or more per year on average. This will occur unless all power transmission lines are buried underground, and it is expected that this will increase even more in Japan due to abnormal weather caused by climate change.
It's easy to think of a 0.2% voltage drop for just 20 seconds, but it has an immeasurable impact on the production equipment of highly IT-enabled factories. Materials and products will be defective, and wasteful time and effort will be wasted until the equipment is stopped or restarted, which will cause great damage to the company.
At this time, the amount of damage caused by the troubles in the equipment should be enormous.
Most of the causes of the instantaneous voltage drop are natural phenomena. It also affects nearby transmission lines that are not directly hit by lightning, such as the B factory, and an instantaneous voltage drop occurs.
Features of VSS ™ (Voltage Sag Protector)
Electric double layer super capacitor (EDLS) is adopted for all models in VSP
○Maintenance-free (battery-less)
Use period of electric double layer capacitor has been extended significantlyEDLSType
By changing the setting, it is possible to back up the instantaneous voltage drop for 1 second or up to 30 seconds (optional).
EDLSIt is easy to instantly charge and supply a large current.
○Light weight, small size, no noise, safe
Light weight, small size and no noise because there is no battery or fan.
The EDLS capacitor has no risk of heat generation and explosion.
○Momentary dip history monitor
You can check the SAG history of 99 times on the front panel.
User can directly set detailed Parliament
○Bypass function
Bypass prevents users from System Shut Down while troubleshooting VSP
○SEMI F47-0706 compatible / CE marking compatible
(LVD/EMC Directive)
F47 is a specification for semiconductor processing equipment voltage sag compatibility CE mark
VSP running cost comparison table
Instantaneous voltage drop protection SEMI F47-0706 compliant standard
Overview of Voltage Sag Protector
Voltage sag protector size chart
Voltage Sag Protector Single Phase
Voltage Type | MODEL / capacity | Size (mm) | weight (kg) | Installation type | Input/output connection type | ||||
Side (W) | Depth (D) | Vertical (H) | 19 inch | Freestanding | Canon connector | Terminal block | |||
100V~ 120V | VSP1103S (300VA) | 180 | 110 | 450 | 10kg | ✖ | 〇 | 〇 | ✖ |
VSP1105S (500VA) | 300 | 400 | 132 | 15kg | 〇 | 〇 | 〇 | ✖ | |
VSP1110S (1kVA) | 300 | 400 | 150 | 17kg | 〇 | 〇 | 〇 | ✖ | |
VSP1120S (2kVA) | 400 | 450 | 180 | 33kg | 〇 | 〇 | 〇 | ✖ | |
VSP1130S (3kVA) | 400 | 450 | 200 | 37kg | 〇 | 〇 | 〇 | 〇 | |
VSP1150S (5kVA) | 430 | 500 | 250 | 51kg | 〇 | 〇 | 〇 | 〇 | |
VSP1110S (10kVA) | 430 | 500 | 250 | 60kg | 〇 | 〇 | ✖ | 〇 | |
200V~ 240V | VSP1203S (300VA) | 180 | 110 | 450 | 10kg | ✖ | 〇 | 〇 | ✖ |
VSP1205S (500VA) | 300 | 400 | 132 | 15kg | 〇 | 〇 | 〇 | ✖ | |
VSP1210S (1kVA) | 300 | 400 | 150 | 17kg | 〇 | 〇 | 〇 | ✖ | |
VSP1220S (2kVA) | 400 | 450 | 180 | 33kg | 〇 | 〇 | 〇 | ✖ | |
VSP1230S (3kVA) | 400 | 450 | 200 | 37kg | 〇 | 〇 | 〇 | 〇 | |
VSP1250S (5kVA) | 430 | 500 | 250 | 51kg | 〇 | 〇 | 〇 | 〇 | |
VSP12100S (10kVA) | 430 | 500 | 250 | 60kg | 〇 | 〇 | 〇 | 〇 |
Voltage Sag Protector3Phase
Voltage Type | MODEL / capacity | Size (mm) | weight (kg) | ||
Side (W) | Depth (D) | Vertical (H) | |||
200V~ 220V | VSP3203S (5kVA) | 600 | 425 | 1045 | 100kg |
VSP3210S (10kVA) | 600 | 425 | 1045 | 130kg | |
VSP3220S (20kVA) | 650 | 380 | 1025 | 200kg | |
VSP3230S (30kVA) | 650 | 460 | 1205 | 300kg | |
VSP3240S (40kVA) | 800 | 500 | 1400 | 400kg | |
VSP3250S (50kVA) | 800 | 500 | 1400 | 450kg | |
VSP3260S (60kVA) | 950 | 503 | 1300 | 500kg | |
VSP3210KS (100kVA) | 1000 | 550 | 1700 | 710kg | |
VSP3212KS (120kVA) | 1200 | 550 | 1700 | 760kg | |
380V~ 440V | VSP3405S (5kVA) | 600 | 425 | 1045 | 100kg |
VSP3410S (10kVA) | 600 | 425 | 1045 | 130kg | |
VSP3420S (20kVA) | 650 | 380 | 1205 | 200kg | |
VSP3430S (30kVA) | 650 | 460 | 1205 | 300kg | |
VSP3440S (40kVA) | 800 | 500 | 1400 | 400kg | |
VSP3450S (50kVA) | 800 | 500 | 1400 | 450kg | |
VSP3460S (60kVA) | 950 | 503 | 1300 | 500kg | |
VSP3410KS (100kVA) | 1000 | 550 | 1700 | 710kg | |
VSP3415KS (150kVA) | 2000 | 546 | 1595 | 850kg |
Voltage Sag Protector Product Catalog
Instantaneous voltage diminishing device VSP PDF Catalog (2013-11-01, 1193KB) |